Version 4 SHEET 1 880 680 WIRE 32 64 -64 64 WIRE 48 64 32 64 WIRE 336 64 304 64 WIRE -64 80 -64 64 WIRE 32 144 32 64 WIRE 48 144 32 144 WIRE 336 144 304 144 WIRE -64 176 -64 160 WIRE 336 224 304 224 WIRE 480 224 336 224 WIRE 560 224 480 224 WIRE 480 240 480 224 WIRE 560 240 560 224 WIRE 48 304 32 304 WIRE 336 304 304 304 WIRE 480 336 480 304 WIRE 560 336 560 320 FLAG 480 336 0 FLAG 32 304 0 FLAG -64 176 0 FLAG 560 336 0 FLAG 336 384 0 FLAG -64 64 IN FLAG 560 224 OUT SYMBOL ind 320 48 R0 SYMATTR InstName L1 SYMATTR Value 1.5µ SYMATTR SpiceLine Rser=80m SYMBOL cap 464 240 R0 SYMATTR InstName C1 SYMATTR Value 10µ SYMBOL voltage -64 64 R0 SYMATTR InstName V1 SYMATTR Value 3.3 SYMBOL res 544 224 R0 SYMATTR InstName Rload SYMATTR Value 50 SYMBOL res 320 208 R0 SYMATTR InstName R1 SYMATTR Value 900K SYMBOL res 320 288 R0 SYMATTR InstName R2 SYMATTR Value 100K SYMBOL ADP2504-ADJ 176 176 R0 SYMATTR InstName U1 TEXT 432 408 Left 2 !.tran 400u startup TEXT 168 -16 Bottom 2 ;PSM and forced PWM modes are modelled\nClock Sync is not modelled